AEM Performance Electronics
2205 126
th
Street Unit A, Hawthorne, CA. 90250
Phone: (310) 484-2322 Fax: (310) 484-0152
http://www.aemelectronics.com
Instruction Part Number: 10-2130 Rev B
© 2011 AEM Performance Electronics
The model 30-2130-XXX family of pressure transducers is specifically designed for pressure measurements in automotive systems. The mechanical
connection is 1/8" Male NPT. Each sensor comes with a mating connector plug and pin kit.
Instruction Manual
P/N 30-2130-XXX Pressure Sensors
KIT CONTENTS
Part Number Sensor Connector Kit -4 Adapter 3/16" Hose Barb
30-2130-15 15 PSIa (1 Bar) Included Included Included
30-2130-30 30 PSIa (2 Bar) Included Included Included
30-2130-50 50 PSIa (3.5 Bar) Included Included Included
30-2130-75 75 PSIa (5 Bar) Included Included Included
30-2130-100 100 PSIg Included Included NA
30-2130-150 150 PSIg Included Included NA
30-2130-500 500 PSIg Included Included NA
30-2130-1000 1000 PSIg Included Included NA
30-2130-2000 2000 PSIg Included Included NA
Specifications:
Accuracy: +/- 1% FS
Temp Error: +/- 1% FS
Operating Temp: -40 to 105C
Burst Pressure: 3 X FS
Supply Voltage: 5V +/- 0.5V
Supply Current: < 6 mA
Response Time: < 1 mS
Vibration: 20G Sinusoidal
Weight: < 85 Grams
Body Material: 304L
Wetted Material: 316L
Mechanical Connection: 1/8”NPT Male
Electrical Connection: Packard 3-Pin
Electrical Termination:
Signal Ground: Tap to Sensor/Signal Ground on EMS or AQ1
Sensor Power: Tap to Sensor Power +5V on EMS or AQ1
Signal: Connect to MAP/Input Channel on EMS or Input 1-8 on AQ1