Installation Instructions for P/N 30-3020
Water/Methanol Failsafe
(Injection Monitor)
WATER/METHANOL FAILSAFE PARTS LIST
This product is legal in California for racing vehicles only and should never be used on public
highways.
WARNING:
!
Completely read this instruction manual before attempting to install or use this
product! This installation is not for the electrically or mechanically challenged!
Use this system with EXTREME caution! Misuse of this system can damage your
engine!
If you are uncomfortable with anything about this, please refer the installation to
an AEM trained tuning shop or call 800-423-0046 for technical assistance. You
should also visit the AEM Performance Electronics Forum at
http://www.aemelectronics.com.
NOTE: AEM holds no responsibility for any engine damage that results from the
misuse of this product!
Qty P/N Description Qty P/N Description
1 35-3020 W/M Failsafe Gauge 1 35-8553W Faceplate 1000 White
1 35-2126 Flow Sensor with Fittings 1 35-8529S Silver Bezel
1 35-3411 8-Pin Power Harness 1 35-4302 Install Kit (6 Butt Connectors)
1 35-3418 4-Pin I/O Harness 1 35-8441 Rubber Band
1 35-3415 3-Pin Sensor Harness 1 10-3020 Inj Mon Instructions
1 35-3010 USB Cable 1 Faceplate Config Instructions
1 35-8552W Faceplate 500 White 1 Needle Removal Tool
1 35-8552B Faceplate 500 Black
Zobrazit stránku 0
1 2 3 4 5 6 ... 17 18

Shrnutí obsahu

Strany 1 - Water/Methanol Failsafe

AEM Performance Electronics 2205 126th Street Unit A, Hawthorne, CA. 90250 Phone: (310) 484-2322 Fax: (310) 484-0152 http://www.aemelectronics.com Ins

Strany 2 - INSTALLATION DIAGRAM

Page 10 4. Review and adjust the high and low flow limit lines as needed to contour the lines around the baseline flow curve by clicking and dragging

Strany 3 - 8 Pin Power Harness

Page 11 DATA LOGGER The Water/Methanol Failsafe has an internal logger that can store approximately 2.5 minutes of injection data. The logger mainta

Strany 4 - Flow vs. Injection Graph

Page 12 Plot One Parameter Description Flow Measured flow rate in cc/min Lower Flow Limit Lower flow limit value as related to Injection Percentage

Strany 5 - Alarm Status

Page 13 OUTPUT CONFIGURATION The Water/Methanol Failsafe has two outputs that are triggered when an alarm condition exists; one +12 volt (high side)

Strany 6 - Alarm Flash

Page 14 NC/NO Relay The following are examples of how a NC/NO relay (Bosch PN 0-332-019-203 or similar) can be configured for use with the Water/Met

Strany 7

Page 15 Warning Light The Water/Methanol Failsafe can also be used to directly activate a warning light (Autometer PN 3239 or similar). Connect the

Strany 8

Page 16 Status Lights The Water/Methanol Failsafe gauge has two status lights (see below) that indicate when an alarm has been triggered. The left s

Strany 9

Page 17 Connector Pinouts The pinouts for the 3-pin sensor harness, 4 pin I/O harness, 8-pin power harness, and 5 pin USB harn

Strany 10 - Page 10

Page 18 12 Month Limited Warranty Advanced Engine Management, Inc. warrants to the consumer that all AEM High Performance products will be free from

Strany 11 - Page 11

Page 2 INSTALLATION DIAGRAM OVERVIEW Water/methanol injection is used to lower air charge temps and reduce detonation which allows for aggressive tu

Strany 12 - Plot Three

Page 3 The Water/Methanol Failsafe also has an auxiliary input that can be used to trigger an alarm condition. Users with the AEM Water/Methanol Inje

Strany 13 - MSD Ignition Products

Page 4 Water/Methanol Failsafe Configuration Tab This is the section where the flow monitoring and alarm output functionality of the Water/Methanol F

Strany 14 - Figure 4

Page 5 Alarm Configuration Option Description Aux Input Status Shows the status of the auxiliary alarm input; on or off Alarm Delay Period of

Strany 15 - Figure 5 Figure 6

Page 6 Gauge Configuration Tab This is the section where the gauge backlighting is configured. Live Gauge View Backlighting Color Option Desc

Strany 16 - Page 16

Page 7 The Water/Methanol Failsafe PC software has a live gauge display. Injection Percentage is shown on the left from 0-100% and flow, in cc/min,

Strany 17 - Page 17

Page 8 WATER/METHANOL FAILSAFE CONFIGURATION The following is a basic guideline strategy for configuring the Water/Methanol Failsafe for the first ti

Strany 18 - Page 18

Page 9 3. With a baseline flow curve now established, click on Auto Set Limits and the software will produce its best suggested high and low flow lim