Universal 8
37
© 2014 AEM Performance Electronics
PINOUTS
Infinity Pinout
Dedicated and not reconfigurable
Assigned but reconfigurable
Not used in this configuration
Required for proper function
7100-XXXX-62
7101-XXXX-63
Function
Lowside switch, 4A max, NO internal
f ly back diode.
Normally used as A/C Relay Control
output. *Pin not populated in 30-3805
Univ ersal V8 Base harness.
Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.
See Setup Wizard Page "LowSide
Assignment Tables" f or output
assignment and 2D table "LS5_Duty [%]"
f or activ ation.
Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.
See Setup Wizard Page "LowSide
Assignment Tables" f or output
assignment and 2D table "LS6_Duty [%]"
f or activ ation.
Lowside switch f or UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor.
NOTE that pin 3 of the Sensor is heater
(+) and must be power by a f used/
switched 12V supply .
Trim Current signal. Connect to pin 2 of
Bosch UEGO sensor.
Pumping Current signal. Connect to pin 6
of Bosch UEGO sensor.
Nernst Voltage signal. Connect to pin 1 of
Bosch UEGO sensor.
Virtual Ground signal. Connect to pin 5 of
Bosch UEGO sensor.
Not usually needed f or automatic
f irmware updates through Infinity Tuner.
If connection errors occur during update,
connect 12 volts to this pin bef ore
proceeding with upgrade. Disconnect the
12 v olts signal after the update.
Dedicated power management CPU
Full time battery power. MUST be
powered bef ore the ignition switch input is
triggered. (See C1-65.)
0–5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.