Universal 8
45
© 2014 AEM Performance Electronics
7100-XXXX-62
7101-XXXX-63
Function
0–5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
0–5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal.
0–5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal. *Pin not populated in 30-
3805 Univ ersal V8 Base harness.
0–5V Falling edge fire. DO NOT connect
directly to coil primary. Must use an
ignitor OR CDI that accepts a FALLING
edge f ire signal. *Pin not populated in 30-
3805 Univ ersal V8 Base harness.
Highside Fuel Pump
Switch*
Highside switch, 0.7A max, Solid State
Relay , NO internal fly back diode.
+12V High Side Driv e. Will prime f or 2
seconds at key on and activ ate if RPM >
0. *Pin not populated in 30-3805 Univ ersal
V8 Base harness.
AEM Infinity Pin Numbering
Viewed From Wire Side